Ohio backflow testing rules

OAC 3745-95-02(C), Ohio EPA, effective Oct 10 2022.

Sources read October 6, 2026. Each section links the pages it came from.

Who sets the rules in Ohio

OAC 3745-95-03(B)(1); community systems may substitute a documented alternate methodology (3745-95-03(B)(2)).

Sources: Every public water system must run a backflow prevention and cross-connection control program; Supplier does periodic on-site investigations of premises at least every five years

Is an annual test required?

OAC 3745-95-06(C)(3): applies to containment-principle backflow preventers required by rules 3745-95-04 and 3745-95-05 (hazard premises and auxiliary-water cases), at the consumer's expense.

OAC 3745-95-06(C)(3).

Source: Required containment backflow preventers must be inspected and tested at least every twelve months

Which properties need a backflow preventer

OAC 3745-95-04(B)(5), unless the director determines no hazard exists. Bulk water loading and temporary hydrant use are also listed.

OAC 3745-95-04(C)(1).

OAC 3745-95-03(A)(2).

OAC 3745-95-05(D): for water-only residential-type irrigation with no pumps or additives.

OAC 3745-95-05(D).

OAC 3745-95-05(C), where an auxiliary water system is a secondary source for a fire system.

Sources: Community systems: listed facility types include hospitals, laboratories, car washes, food plants; Residential premises: no initial assessment per premises if the supplier has an alternate method; Residential-type irrigation: pressure vacuum breaker allowed, testing rule still applies

Who may do the test

OAC 3745-95-06(C)(3). No state tester licence is named in the rule; each supplier approves its testers.

Source: Inspections and tests must be done by a person approved by the supplier and acceptable to the director

How the test report is filed

OAC 3745-95-06(C)(5). No deadline stated.

OAC 3745-95-06(C)(6).

Source: Consumer keeps test records and makes them available to the supplier

If a test is missed

OAC 3745-95-08(A); service is not restored until the defect is fixed to the supplier's satisfaction.

OAC 3745-95-08(A)(1).

Source: Supplier must deny or discontinue service after reasonable notice

Common questions

Is backflow testing required every year in Ohio?

OAC 3745-95-06(C)(3): applies to containment-principle backflow preventers required by rules 3745-95-04 and 3745-95-05 (hazard premises and auxiliary-water cases), at the consumer's expense.